🧾 Description

The compatible modules with Profinet are:
 

  • Model :     CM9681-N100
    Description :     CM9681 Connection Module, Ethernet / Profinet, IP65 - (M12 connectors)
     

  • Model :     CM9680 (N100)
    Description :     CM9680 Connection Module, Ethernet / Profinet - (RJ connector).

🛠️ Resolution Steps

The base BC968x must be powered ON.
The reader must be linked to the base.
The base must be set with interface “ETH-STD1”.
These settings can be configured using the Aladdin tool or by scanning the following configuration label:
 
  1. Scan Unlink:

    Then put physically the reader on the base and wait up beeps.

  2. Restore default:

    This is to reset the reader AND the base.

  3. Interface Eth STD1:

  4. Restore Default the CM968x:

    This will reset the CM and back to default IP address : 192.168.187.31
    After that, turn off the base and plug it back in.

  5. Now connect the base to your local network and open Aladdin.
    In Aladdin tool, it should display as follow:


    After that, you can change the Ip address and the Gateway by clicking on the CM icon and do “apply” to save the configuration and “close”:



    Then, you should get as follow.
    On this example, it concern a Powerscan Bluetooth:

    PS: The reader will never be displayed. Only the CM and the base.

    About Profinet configuration, you will find all information in the manuals attached.
    You will find also some programs samples for TIA Portal and the GSDML file.

 