----------------------------------- Datalogic, 9 November 2023 ------------------------------------

Project:		TestProject-CM968x.ap14
Environment: 		Siemens T.I.A. Portal v.14
Communication Protocol: PROFINET-IO RT
GSDML file: 		GSDML-V2.42-Datalogic-CM9681-N100-20220608.xml
GSDML bitmap:		GSDML-019C-0601-Datalogic-CM9681-N100.bmp
----------------------------------------------------------------------------------

PNIO Controller:	PLC Siemens S71511-PN
PNIO Device:		CM9681-N100
PNIO Device I/O:	128 bytes IN(device-->PLC), 16 bytes OUT(PLC-->device)
----------------------------------------------------------------------------------

The project establishes a PNIO basic connection between the Controller and the device. No additional activities are implemented by program blocks.

Two watch tables have been defined to allow the data monitor according to the current IO mapping:
- INPUT bytes from address 2 to address 129 
- OUTPUT bytes from address 2 to address 17