🧾 Description
The following configuration applies Datalogic MAGELLAN 1500i running on a French operating system.
This is the most commonly requested configuration.
🛠️ Resolution Steps
Scan in following order:
-
Return Factory Settings
-
Enter in configuration mode (Switch Label)
-
USB Keyboard Interface
-
Country Mode = France
-
CapsLock compensation
-
Datamatrix Enable
-
Disable Label ID
-
Exit configuration mode (Switch Label)
Wait for the reader to restart before continuing with the configuration.
Optionnal settings:
-
Enter in configuration mode (Switch Label)
-
2D inverse (white pixels on black background + Normal)
-
Enter in configuration mode (Switch Label)
Wait for the reader to restart. Reader is ready.
-
Enter in configuration mode (Switch Label)
-
Interleaved2of5 (Tickets Restaurants)
-
1D_VL_TIME_SHARED
-
Enter in configuration mode (Switch Label)
Wait for the reader to restart. Reader is ready.