🧾 Description

Concatenation feature allows the concatenation of Two Codes define by code type and length. It is possible to set a Timeout for the second code reading and to define code tranmission if timeout expires. Since you can concatenate codes from different families, you must select the Code ID character fo the resulting code. The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection

🛠️ Resolution Steps

First step is to Enable the general Advanced Formatting and to select the No Match Result of the rules you are going to apply:

  • Clear Data - No Transmission: if the rule will not match, no codes will be transmistted

  • Transmit data using standard format: if the rule will not match, codes will be transmitted without any changes

 

 

Then enable general Concatenation and select the code Types and Legth to be concatenated. Furthermore the Result Code Type, Timeout between readings and option if timeout expires (no code transmission, 1st code, 2nd code, either 1st or 2nd codes):

 

Now go to the three top lines to select Export Configuration and get the configuration in codes:

 

 