🧾 Description

By default, when address stamping is enabled the PowerScan M9600 uses a 12 hex digit address, for example, 0000002139AE<Message>
With the following setting it is possible to reduce the address size at 4 digit (in the range 0001 to 1999) in order to be compatible with old host working with this format.

🛠️ Resolution Steps

  1. Source Radio Address Transmit = Enable

 

 

     2. Enabled 4-digt address

 

 

      3. Select the 4 digit addres in the range 0001 to 1999:

A. Enter Programming Mode

 

 

B. Assign Unique Address

 

 

C. 4 couples of digits (in hex), for example, if radio address is 1234 = 31323334. When reading last number of the 4 couples, the reader will emit 2 BEEPs in a row:

           0                                                         1                                                             2

                                                                                   

 

 

         3                                                           4                                                             5

                                                                                   
 
 
        6                                                           7                                                              8
                                                                                   
 
 

         9

 

 

D. Exit Programming Mode

 

 

Add a comment