🧾 Description
By default, when address stamping is enabled the PowerScan M9600 uses a 12 hex digit address, for example, 0000002139AE<Message>
With the following setting it is possible to reduce the address size at 4 digit (in the range 0001 to 1999) in order to be compatible with old host working with this format.
With the following setting it is possible to reduce the address size at 4 digit (in the range 0001 to 1999) in order to be compatible with old host working with this format.
🛠️ Resolution Steps
Source Radio Address Transmit = Enable
2. Enabled 4-digt address
3. Select the 4 digit addres in the range 0001 to 1999:
A. Enter Programming Mode
B. Assign Unique Address
C. 4 couples of digits (in hex), for example, if radio address is 1234 = 31323334. When reading last number of the 4 couples, the reader will emit 2 BEEPs in a row:
0 1 2
3 4 5
6 7 8
9
D. Exit Programming Mode