🧾 Description
It appears in any of the USB Keyboard interfaces and connected to a modern Windows 11 Notepad, the barcode output is delayed and erratic.
The behavior.
- Scanning a barcode, only few of the first characters is seen.
- Scan a second label, the next few character from the original barcode transmitted
- Scan more labels, the missing data slowly appears in notepad.
- If stop scanning and wait for a bit of time, eventually all the data will auto appear.
(NOTE: If scanning a bunch of label and seeing partial data, you can remove the USB cable from the port and the data will still populate into Notepad by either pressing the Enter key or wait until is auto populates. So the data is buffered in the pc. )
Application: NOTEPAD version 10.0.229221.1
This behavior is only seen with Win11 Notepad. Older version of notepad, MS word, web browser and Outlook, this issue is not seen.
The behavior.
- Scanning a barcode, only few of the first characters is seen.
- Scan a second label, the next few character from the original barcode transmitted
- Scan more labels, the missing data slowly appears in notepad.
- If stop scanning and wait for a bit of time, eventually all the data will auto appear.
(NOTE: If scanning a bunch of label and seeing partial data, you can remove the USB cable from the port and the data will still populate into Notepad by either pressing the Enter key or wait until is auto populates. So the data is buffered in the pc. )
Application: NOTEPAD version 10.0.229221.1
This behavior is only seen with Win11 Notepad. Older version of notepad, MS word, web browser and Outlook, this issue is not seen.
🛠️ Resolution Steps
Temporary fix, set a higher USB speed. Gryphon 4500 and QuickScan 2500 set to 3ms works. Or, increase until the transmits normally.