🧾 Description
This procedure explains how to configure Handhelds 2D scanners for using on Gilbarco Systems.
🛠️ Resolution Steps
Next scan the barcode below and then Reboot the Gilbarco system.
$P,HA05,CR2PA01,CR2DA00,CC3EN01,CC8EN00,CEBAB01,P
HA05 = RS232 Interface
CR2PA01 = Even Parity
CR2DA00 = 7 Data bits
CC3EN01 = Code39 Enabled
CC8EN00 = Code128 Disabled
CEBAB01 = UPC-E to UPC-A Expansion
Once the Gilbarco system finishes rebooting, give the scanner a test by scanning some data barcodes and see if everything is working correctly.