🧾 Description & General Info

This article explains the procedure to Export/Import a Custom Configuration File in Handheld Scanners
 

 

🛠️ Resolution Steps

Export ccf file

 

  1. Enable the Aladdin SW to Developer mode
  • click the right button of the mouse over the Aladdin icon on the desktop à Properties à add in the Location window a ‘space’ and ‘+d’, please refer to the below screenshot


 
 

  1. Launch the Aladdin SW

 

  1. If the interface is set equal to RS232 or USB-COM access directly otherwise if the interface set is equal to USB-KBD then use the option: Tools à Force Device Connection. In this last case please follow the next steps:
  • Do not browse the com port and do not click connect device if one port (e.g COMx) is detected by the software.

 

 
  •  
    • Be sure to have disconnected the USB cable from the computer and connect it again while pressing the button of the base or the trigger if a desk model is used. If you are using a cradle for the Quickscan model or RIDA DBT6400 or the Cobalto device then keep pressed the hidden button (present in the bottom of the cradle) using a clip while plugging the USB cable.

 

CobaltoQuickscan cradle
 
 
RIDA cradle
 
 

 

  • When the dialogue window changes to “USB HID”, click on “Connect device” while keeping pressed the button.

 

 
  •  
    • When the Wait loading bar appears release the button.
    • Access the product configuration

 

  1. In Expert Mode à Custom Configuration File à click Read

 
 

  1. Once the text box will be populated, click on Save à choose the type file (.txt)


 
 

  1. This file can be used to load the configuration on another device (same product) connected to Aladdin by simply loading the previous file and then writing it.

 

 

 

Import ccf file

 

  1. Enable the Aladdin SW to Developer mode
  • click the right button of the mouse over the Aladdin icon on the desktop à Properties à add in the Location window a ‘space’ and ‘+d’, please refer to the below screenshot



 

  1. Launch the Aladdin SW

 

  1. If the interface is set equal to RS232 or USB-COM access directly otherwise if the interface set is equal to USB-KBD then use the option: Tools à Force Device Connection. In this last case please follow the next steps:
  • Do not browse the com port and do not click connect device if one port (e.g COMx) is detected by the software.

 

 
  •  
    • Be sure to have disconnected the USB cable from the computer and connect it again while pressing the button of the base or the trigger if a desk model is used. If you are using a cradle for the Quickscan model or RIDA DBT6400 or the Cobalto device then keep pressed the hidden button (present in the bottom of the cradle) using a clip while plugging the USB cable.

 

CobaltoQuickscan cradle
 
 
RIDA cradle
 
 

 

  •  
    • When the dialogue window changes to “USB HID”, click on “Connect device” while keeping pressed the button.

 

 
  •  
    • When the Wait loading bar appears release the button.
    • Access the product configuration

 

  1. In Expert Mode à Custom Configuration File à click Load



 

  1. Select the proper CCF file



 

  1. Once the text box will be populated, click on Write and wait for the process to finish.



 

  1. If an ULE is present, then it is necessary to go on the ULE tab, select the Enabled option and click Write Configuration



 

  1. Once completed, simply disconnect the device, by clicking the highlighted icon:


 

 